Model | STANDARD | Dual pipe (identical probes) | Dual chord |
Nature of equipment | Fixed | Fixed | Fixed |
Measurement on pipe under load | Yes | Yes | Yes |
Flow measurement on open channel | No | No | No |
Internal o of pipe | From 8mm to 600mm approximately (depending on wall thickness) | From 8mm to 600mm approximately (depending on wall thickness) | From 8mm to 600mm approximately (depending on wall thickness) |
External o of pipe | From 10mm to 630mm | From 10mm to 630mm | From 10mm to 630mm |
Inputs/Outputs | › 2 current outputs, 4-20mA (1000Ω galvanically isolated as a passive output/impedance of 150Ω | › 2 current outputs, 4-20mA (1000Ω galvanically isolated as a passive output/impedance of 150Ω | › 2 current outputs, 4-20mA (1000Ω galvanically isolated as a passive output/impedance of 150Ω |
Use | Flow measurement Flow measurement in two pipes Flow measurement | Flow measurement Flow measurement in two pipes Flow measurement | Flow measurement Flow measurement in two pipes Flow measurement |
Single or dual pipe | Single pipe | Dual pipe: for two pipes that might have different diameters and thicknesses, be made of different materials, but which must use same probes | Single pipe |
Single or dual chord | Single chord | Single chord | Dual chord |
Display | › Alphanumeric and graphical (2 lines x 16 characters) | › Alphanumeric and graphical (2 lines x 16 characters) | › Alphanumeric and graphical (2 lines x 16 characters) |
Set-up | › Q uick and simple using 4-key touch pad - or - via dedicated software supplied | › Q uick and simple using 4-key touch pad - or - via dedicated software supplied | › Q uick and simple using 4-key touch pad - or - via dedicated software supplied |
Operating system | Windows for set-up and saving application data | Windows for set-up and saving application data | Windows for set-up and saving application data |
7 languages | French • English • German • Portuguese • Spanish • Italian • Polish | French • English • German • Portuguese • Spanish • Italian • Polish | French • English • German • Portuguese • Spanish • Italian • Polish |
Serial link | RS232 or RS485 to JBUS/MODBUS protocol • 9600 Bauds | RS232 or RS485 to JBUS/MODBUS protocol • 9600 Bauds | RS232 or RS485 to JBUS/MODBUS protocol • 9600 Bauds |
Accessory (optional) | 1 RS232 to USB converter link cable | 1 RS232 to USB converter link cable | 1 RS232 to USB converter link cable |
Basic pow er supply | Low voltage: 9-36V dc or 7-25V ac (5VA) | Low voltage: 9-36V dc or 7-25V ac (5VA) | Low voltage: 9-36V dc or 7-25V ac (5VA) |
Optional pow er supply | 18-72V dc or 90-230V ac (5VA) | 18-72V dc or 90-230V ac (5VA) | 18-72V dc or 90-230V ac (5VA) |
Enclosure | Cast aluminium & epoxy paint • 1.5kg • 237 x 108 x 79mm | Cast aluminium & epoxy paint • 1.5kg • 237 x 108 x 79mm | Cast aluminium & epoxy paint • 1.5kg • 237 x 108 x 79mm |
Protection | IP67 | IP67 | IP67 |
Temperature range | For use from 0°C to 50°C (60°C on demand) | For use from 0°C to 50°C (60°C on demand) | For use from 0°C to 50°C (60°C on demand) |