Minisonic 600 - Flow meter

Minisonic 600 - Flow meter
 
 
Model
STANDARD
Dual pipe (identical probes)
Dual chord
Nature of equipment
Fixed
Fixed
Fixed
Measurement
on pipe under load
Yes
Yes
Yes
Flow measurement
on open channel
No
No
No
Internal o of pipe
From 8mm to 600mm approximately (depending on wall thickness)
From 8mm to 600mm approximately (depending on wall thickness)
From 8mm to 600mm approximately (depending on wall thickness)
External o of pipe
From 10mm to 630mm
From 10mm to 630mm
From 10mm to 630mm
Inputs/Outputs
› 2 current outputs, 4-20mA (1000Ω galvanically isolated as a passive output/impedance of 150Ω
› 2 current outputs, 4-20mA (1000Ω galvanically isolated as a passive output/impedance of 150Ω
› 2 current outputs, 4-20mA (1000Ω galvanically isolated as a passive output/impedance of 150Ω
Use
Flow measurement Flow measurement in two pipes Flow measurement
Flow measurement Flow measurement in two pipes Flow measurement
Flow measurement Flow measurement in two pipes Flow measurement
Single or dual pipe
Single pipe
Dual pipe: for two pipes that
might have different diameters
and thicknesses, be made of
different materials, but which
must use same probes
Single pipe
Single or dual chord
Single chord
Single chord
Dual chord
Display
› Alphanumeric and graphical (2 lines x 16 characters)
› Alphanumeric and graphical (2 lines x 16 characters)
› Alphanumeric and graphical (2 lines x 16 characters)
Set-up
› Q uick and simple using 4-key touch pad - or - via dedicated software supplied
› Q uick and simple using 4-key touch pad - or - via dedicated software supplied
› Q uick and simple using 4-key touch pad - or - via dedicated software supplied
Operating system
Windows for set-up and saving application data
Windows for set-up and saving application data
Windows for set-up and saving application data
7 languages
French • English • German • Portuguese • Spanish • Italian • Polish
French • English • German • Portuguese • Spanish • Italian • Polish
French • English • German • Portuguese • Spanish • Italian • Polish
Serial link
RS232 or RS485 to JBUS/MODBUS protocol • 9600 Bauds
RS232 or RS485 to JBUS/MODBUS protocol • 9600 Bauds
RS232 or RS485 to JBUS/MODBUS protocol • 9600 Bauds
Accessory (optional)
1 RS232 to USB converter link cable
1 RS232 to USB converter link cable
1 RS232 to USB converter link cable
Basic pow er supply
Low voltage: 9-36V dc or 7-25V ac (5VA)
Low voltage: 9-36V dc or 7-25V ac (5VA)
Low voltage: 9-36V dc or 7-25V ac (5VA)
Optional pow er supply
18-72V dc or 90-230V ac (5VA)
18-72V dc or 90-230V ac (5VA)
18-72V dc or 90-230V ac (5VA)
Enclosure
Cast aluminium & epoxy paint • 1.5kg • 237 x 108 x 79mm
Cast aluminium & epoxy paint • 1.5kg • 237 x 108 x 79mm
Cast aluminium & epoxy paint • 1.5kg • 237 x 108 x 79mm
Protection
IP67
IP67
IP67
Temperature range
For use from 0°C to 50°C (60°C on demand)
For use from 0°C to 50°C (60°C on demand)
For use from 0°C to 50°C (60°C on demand)

REQUEST FORM