Minisonic G-Flow Meter

Minisonic G-Flow Meter
 
MODEL
STANDARD
Dual pipe (identical probes)
Dual chord
Nature of equipment
Fixed
Fixed
Fixed
Internal o of pipe
From 8mm to 1,400mm approximately (depending on wall thickness)
From 8mm to 1,400mm approximately (depending on wall thickness)
From 8mm to 1,400mm approximately (depending on wall thickness)
External o of pipe
From 10mm to 1,500mm
From 10mm to 1,500mm
From 10mm to 1,500mm
Inputs/Outputs
› 2 current outputs, 4-20mA (1000Ω galvanically isolated as a passive output/impedance of 150Ω
as an active output)
› 2 static relay outputs (100V - 100mA - 10VA max)
› 2 current outputs, 4-20mA (1000Ω galvanically isolated as a passive output/impedance of 150Ω
as an active output)
› 2 static relay outputs (100V - 100mA - 10VA max)
› 2 current outputs, 4-20mA (1000Ω galvanically isolated as a passive output/impedance of 150Ω
as an active output)
› 2 static relay outputs (100V - 100mA - 10VA max)
Use
Flow measurement
Flow measurement in two pipes
Flow measurement
with two speed chords
Single or dual pipe
Single pipe
Dual pipe: for two pipes that
might have different diameters
and thicknesses, be made of
different materials, but which
must use same probes
Single pipe
Single or dual chord
Single chord
Single chord
Dual chord
in option ,
explosion-proof
enclosure
› Available
› Certified ATEX  E Ex d IIC T6
› Available
› Please ask us
› Available
› Please ask us
Display
› A lphanumeric and graphical (2 lines x 16 characters)
› Backlit LCD screen with time delay feature
› A lphanumeric and graphical (2 lines x 16 characters)
› Backlit LCD screen with time delay feature
› A lphanumeric and graphical (2 lines x 16 characters)
› Backlit LCD screen with time delay feature
Set-up
› Q uick and simple using 4-key touch pad - or - via dedicated software supplied
› P ossible to build in an access code
› Q uick and simple using 4-key touch pad - or - via dedicated software supplied
› P ossible to build in an access code
› Q uick and simple using 4-key touch pad - or - via dedicated software supplied
› P ossible to build in an access code
Operating system
Windows for set-up and saving application data
Windows for set-up and saving application data
Windows for set-up and saving application data
7 languages
French • English • German • P ortuguese • Spanish • It alian • P olish
French • English • German • P ortuguese • Spanish • It alian • P olish
French • English • German • P ortuguese • Spanish • It alian • P olish
Serial link
RS232 or RS 485 to JBUS /MODBUS pr otocol • 9600 Bauds
RS232 or RS 485 to JBUS /MODBUS pr otocol • 9600 Bauds
RS232 or RS 485 to JBUS /MODBUS pr otocol • 9600 Bauds
Accessory (optional)
1 RS232 to USB converter link cable
1 RS232 to USB converter link cable
1 RS232 to USB converter link cable
Basic power supply
Low v oltage: 9- 36V dc or 7 -25Vac (5 VA)
Low v oltage: 9- 36V dc or 7 -25Vac (5 VA)
Low v oltage: 9- 36V dc or 7 -25Vac (5 VA)
Optional power supply
18-72V dc or 90- 230Vac (5 VA)
18-72V dc or 90- 230Vac (5 VA)
18-72V dc or 90- 230Vac (5 VA)
Enclosure
Cast aluminium & epo xy pain t • 1.5kg • 2 37 x 108 x 79mm
Cast aluminium & epo xy pain t • 1.5kg • 2 37 x 108 x 79mm
Cast aluminium & epo xy pain t • 1.5kg • 2 37 x 108 x 79mm
explosion-proof
enclosure
Cast aluminium & epo xy pain t • 6.6kg • 244 x 130 x 232mm
Cast aluminium & epo xy pain t • 6.6kg • 244 x 130 x 232mm
Cast aluminium & epo xy pain t • 6.6kg • 244 x 130 x 232mm
Protection
IP 67
IP 67
IP 67
Temperature range
For use from 0°C to 50°C
For use from 0°C to 50°C
For use from 0°C to 50°C

REQUEST FORM
minisonic g-flow meter