MODEL | STANDARD | STANDARD explosion proof | PORTABLE |
Nature of equipment | Fixed | Fixed | Portable |
Detection in pipe under load | Yes | Yes | Yes |
Flow measurement on open channel | No | No | No |
External o of pipe | 100mm to 1500mm / 4’’ to 60’’ | 100mm to 1500mm / 4’’ to 60’’ | 100mm to 1500mm / 4’’ to 60’’ |
Inputs/Outputs | › 2 analogue outputs › 2 static relay outputs | › 2 analogue outputs › 2 static relay outputs | › 2 analogue outputs › 2 static relay outputs |
Use | Detection of the passing of a sphere or pig and change of product in the pipe | Detection in an explosive environment of the passing of a sphere or pig and change of product in the pipe | Detection of the passing of a sphere or pig and change of product in the pipe |
In option, 2U 19’ ’ rack | Available | ||
Single or dual pipe | Single pipe | Single pipe | Single pipe |
Single or dual chord | Single chord | Single chord | Single chord |
Display | › Alphanumeric (2 lines x 16 characters) › Backlit LCD screen with time delay feature | › Alphanumeric (2 lines x 16 characters) › Backlit LCD screen with time delay feature | › Alphanumeric (2 lines x 16 characters) › Backlit LCD screen with time delay feature |
Set-up | › Q uick and simple using 4-key touch pad - or - via dedicated software supplied › P ossible to build in an access code | › Q uick and simple using 4-key touch pad - or - via dedicated software supplied › P ossible to build in an access code | › Q uick and simple using 4-key touch pad - or - via dedicated software supplied › P ossible to build in an access code |
Operating system | Windows for set-up and saving application data | Windows for set-up and saving application data | Windows for set-up and saving application data |
6 langues | French • English • German • Portuguese • Spanish • Italian | French • English • German • Portuguese • Spanish • Italian | French • English • German • Portuguese • Spanish • Italian |
Serial link | RS232 or RS485 to JBUS/MODBUS protocol • 9600 Bauds | RS232 or RS485 to JBUS/MODBUS protocol • 9600 Bauds | RS232 to JBUS/MODBUS protocol • 9600 Bauds |
Accessory (optional) | 1 RS232 to USB converter link cable | 1 RS232 to USB converter link cable | 1 RS232 to USB converter link cable |
ELECTRICAL CHARACTERISTICS | › 2 Static relays (100V - 100mA - 10VA max) › 1 RS232/RS485 serial link to MODBUS/JBUS protocol › Basic power supply • Low voltage: 9-36V dc or 7-25V ac › Optional power supply 18-72V dc or 90-230 V ac › 2 current outputs, 4-20mA (1000 Ω galvanically isolated as passive output/150 Ω impedance as an active output) | › 2 Static relays (100V - 100mA - 10VA max) › 1 RS232/RS485 serial link to MODBUS/JBUS protocol › Basic power supply • Low voltage: 9-36V dc or 7-25V ac › Optional power supply 18-72V dc or 90-230 V ac › 2 current outputs, 4-20mA (1000 Ω galvanically isolated as passive output/150 Ω impedance as an active output) | › 2 Static relays (100V - 100mA - 10VA max) › 1 RS 232 serial link to MODBUS/JBUS protocol › 12V NiMh sealed internal battery › 100-240V ac charger and aux. power supply function › 2 active current outputs, 4-20mA (150Ω impedance) |
Enclosure | › C ast aluminium & epoxy paint › 1.5kg • 237 x 108 x 79mm | › C ast aluminium & epoxy paint › 6.6kg • 244 x 130 x 232mm | › ABS •Supplied with a slip caseand storage bag › 835g • 220 x 115 x 64mm |
Protection | IP67 (except rack 19’’) | IP67 | |
Temperature range | For use from 0°C to 50°C | For use from 0°C to 50°C | For use from 0°C to 50°C |