Minisonic P -FLOW METER

Minisonic P -FLOW METER
 
 
MODEL
STANDARD
DUAL PÄ°PE
DUAL CHORD
Nature of equipment
Portable
Portable
Portable
Measurement
on pipe under load
Yes
Yes
Yes
Flow measurement
on open channel
No
No
No
Internal o of pipe
From 8mm to 3,200mm (depending on wall thickness)
From 8mm to 3,200mm (depending on wall thickness)
From 8mm to 3,200mm (depending on wall thickness)
External o of pipe
From 10mm to 3,300mm
From 10mm to 3,300mm
From 10mm to 3,300mm
Inputs/Outputs
› 2 active current outputs, 4-20mA (impedance 150Ω)
› 2 static relay outputs (100V - 100mA - 10VA max)
› 2 active current outputs, 4-20mA (impedance 150Ω)
› 2 static relay outputs (100V - 100mA - 10VA max)
› 2 active current outputs, 4-20mA (impedance 150Ω)
› 2 static relay outputs (100V - 100mA - 10VA max)
Use
Flow measurement
Flow measurement in two pipes
Flow measurement
with two speed chords
Single or dual pipe
Single pipe
Dual pipe: for two pipes that
might have different diameters
and thicknesses, be made of
different materials, but which
must use same probes
Single pipe
Single or dual chord
Single chord
Single chord
Dual chord
Display
› Alphanumeric and graphical (2 lines x 16 characters)
› Backlit LCD screen with time delay feature
› Alphanumeric and graphical (2 lines x 16 characters)
› Backlit LCD screen with time delay feature
› Alphanumeric and graphical (2 lines x 16 characters)
› Backlit LCD screen with time delay feature
Set-up
› Quick and simple using 4-key touch pad - or - via dedicated software supplied
›  Possible to build in an access code
› Quick and simple using 4-key touch pad - or - via dedicated software supplied
› Possible to build in an access code
› Quick and simple using 4-key touch pad - or - via dedicated software supplied
› Possible to build in an access code
Information collection
› Either by current output connected to an external logger (USB LOGGE R option)
› Or by a serial link connected to the computer (Excel macro built into the Ultraflux software)
› Either by current output connected to an external logger (USB LOGGE R option)
› Or by a serial link connected to the computer (Excel macro built into the Ultraflux software)
› Either by current output connected to an external logger (USB LOGGE R option)
› Or by a serial link connected to the computer (Excel macro built into the Ultraflux software)
Operating system
Windows for set-up and saving application data
Windows for set-up and saving application data
Windows for set-up and saving application data
7 languages
French • English • German • Portuguese • Spanish • Italian • Polish
French • English • German • Portuguese • Spanish • Italian • Polish
French • English • German • Portuguese • Spanish • Italian • Polish
Battery life
Up to 40hr (charging takes 12 to 14hr)
Up to 40hr (charging takes 12 to 14hr)
Up to 40hr (charging takes 12 to 14hr)
Serial link
RS232 to JBUS/MODBUS protocol • 9600 Bauds
RS232 to JBUS/MODBUS protocol • 9600 Bauds
RS232 to JBUS/MODBUS protocol • 9600 Bauds
Accessory (optional)
1 RS232 to USB converter link cable
1 RS232 to USB converter link cable
1 RS232 to USB converter link cable
ELECT RICAL
CHARACTE RISTICS
› 12V NiMh sealed battery
› Charger with input: 100-240V ac / 400mA / 47-63Hz and output: 15V / 1A
› Cable for auxiliary power supply available as an option
› 12V NiMh sealed battery
› Charger with input: 100-240V ac / 400mA / 47-63Hz and output: 15V / 1A
› Cable for auxiliary power supply available as an option
› 12V NiMh sealed battery
› Charger with input: 100-240V ac / 400mA / 47-63Hz and output: 15V / 1A
› Cable for auxiliary power supply available as an option
Enclosure
ABS, supplied with a slip case and storage bag • 835g • 220 x 115 x 64mm
ABS, supplied with a slip case and storage bag • 835g • 220 x 115 x 64mm
ABS, supplied with a slip case and storage bag • 835g • 220 x 115 x 64mm
Protection
IP 67
IP 67
IP 67
Temperature range
For use from 0°C to 50°C
For use from 0°C to 50°C
For use from 0°C to 50°C

REQUEST FORM
minisonic p -flow meter