Uf811 - FLOW METER

Uf811 - FLOW METER
 
 
Model
Standard
Dual pipe
Dual chord
Calorimeter
Dual calorimeter
Internal ø of pipe
From 8mm to 9,900mm approximately (depending on wall thickness)
From 8mm to 9,900mm approximately (depending on wall thickness)
From 8mm to 9,900mm approximately (depending on wall thickness)
From 8mm to 9,900mm approximately (depending on wall thickness)
From 8mm to 9,900mm approximately (depending on wall thickness)
External ø of pipe
From 10mm to 10,000mm
From 10mm to 10,000mm
From 10mm to 10,000mm
From 10mm to 10,000mm
From 10mm to 10,000mm
LT configuration
- dual module -
 
 
 
PT 100/PT 1000 2-input module taking up
PT 100/PT 1000 2-input module taking up
Supplementary LT
configuration
(dual calorimetry)
- dual module -
 
 
 
 
PT 100/PT 1000
2-input module taking
up the physical space
of two modules
Use
Flow measurement
Flow measurement
in two pipes
Flow measurement
with two speed
chords
Flow measurement
and calorimetry
Flow measurements
in two pipes and
dual calorimetry
Single or dual pipe
Single pipe
Dual pipe
Single pipe
Single pipe
Dual pipe
Single or dual chord
Single chord
Single chord
Dual pipe
Single chord
Single chord
In option,
supplementary
input/output single
modules
Up to 4 modules
to choose from:
› 1 isolated, active analogue output: current 4-20mA, 0-20mA, 0-24mA • Module 1
› 2 static relay outputs (50V - 10mA) usable as frequency outputs
(up to 1kHz) • Module 2
› 2 isolated, passive current inputs 4-20mA, 0-20mA, 0-24mA • Module 3
› 2 isolated, passive analogue 0-10V inputs: 0 to 15V voltage • Module 4
› 2 contact 5V inputs (pulse or state) • Module 6
› 1 isolated, active analogue output: current 4-20mA, 0-20mA, 0-24mA • Module 1
› 2 static relay outputs (50V - 10mA) usable as frequency outputs
(up to 1kHz) • Module 2
› 2 isolated, passive current inputs 4-20mA, 0-20mA, 0-24mA • Module 3
› 2 isolated, passive analogue 0-10V inputs: 0 to 15V voltage • Module 4
› 2 contact 5V inputs (pulse or state) • Module 6
› 1 isolated, active analogue output: current 4-20mA, 0-20mA, 0-24mA • Module 1
› 2 static relay outputs (50V - 10mA) usable as frequency outputs
(up to 1kHz) • Module 2
› 2 isolated, passive current inputs 4-20mA, 0-20mA, 0-24mA • Module 3
› 2 isolated, passive analogue 0-10V inputs: 0 to 15V voltage • Module 4
› 2 contact 5V inputs (pulse or state) • Module 6
Up to 2 modules
to choose from:
› 1 isolated, active analogue output: current 4-20mA, 0-20mA, 0-24mA • Module 1
› 2 static relay outputs (50V - 10mA) usable as frequency outputs
(up to 1kHz) • Module 2
› 2 isolated, passive current inputs 4-20mA, 0-20mA, 0-24mA • Module 3
› 2 isolated, passive analogue 0-10V inputs: 0 to 15V voltage • Module 4
› 2 contact 5V inputs (pulse or state) • Module 6
 
Display
› G raphical LCD screen (14 lines x 20 characters)
› Backlit screen with time delay feature
› G raphical LCD screen (14 lines x 20 characters)
› Backlit screen with time delay feature
› G raphical LCD screen (14 lines x 20 characters)
› Backlit screen with time delay feature
› G raphical LCD screen (14 lines x 20 characters)
› Backlit screen with time delay feature
› G raphical LCD screen (14 lines x 20 characters)
› Backlit screen with time delay feature
Troubleshooting help
Oscilloscope function (echo displayed) • Gain • Quality index
Oscilloscope function (echo displayed) • Gain • Quality index
Oscilloscope function (echo displayed) • Gain • Quality index
Oscilloscope function (echo displayed) • Gain • Quality index
Oscilloscope function (echo displayed) • Gain • Quality index
Set-up
› Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› P ossible to build in an access code
› Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› P ossible to build in an access code
› Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› P ossible to build in an access code
› Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› P ossible to build in an access code
› Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› P ossible to build in an access code
Information storage
› 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 lines
› 3-variable time stamping: 268,443 lines • 14 variables: 71,584 lines • 30 variables: 34,637 lines
› L ogging frequency from 1 second to 24 hours
› 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 lines
› 3-variable time stamping: 268,443 lines • 14 variables: 71,584 lines • 30 variables: 34,637 lines
› L ogging frequency from 1 second to 24 hours
› 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 lines
› 3-variable time stamping: 268,443 lines • 14 variables: 71,584 lines • 30 variables: 34,637 lines
› L ogging frequency from 1 second to 24 hours
› 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 lines
› 3-variable time stamping: 268,443 lines • 14 variables: 71,584 lines • 30 variables: 34,637 lines
› L ogging frequency from 1 second to 24 hours
› 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 lines
› 3-variable time stamping: 268,443 lines • 14 variables: 71,584 lines • 30 variables: 34,637 lines
› L ogging frequency from 1 second to 24 hours
Operating system
Windows for transfer of content and operation of logger using common software (Excel, etc.)
Windows for transfer of content and operation of logger using common software (Excel, etc.)
Windows for transfer of content and operation of logger using common software (Excel, etc.)
Windows for transfer of content and operation of logger using common software (Excel, etc.)
Windows for transfer of content and operation of logger using common software (Excel, etc.)
7 languages
French • English • German • Portuguese • Spanish • Italian • Russian
French • English • German • Portuguese • Spanish • Italian • Russian
French • English • German • Portuguese • Spanish • Italian • Russian
French • English • German • Portuguese • Spanish • Italian • Russian
French • English • German • Portuguese • Spanish • Italian • Russian
Communication
› Serial link RS232 or RS485 to JBUS/MODBUS protocol • 115,200 Bauds
› USB port
› Serial link RS232 or RS485 to JBUS/MODBUS protocol • 115,200 Bauds
› USB port
› Serial link RS232 or RS485 to JBUS/MODBUS protocol • 115,200 Bauds
› USB port
› Serial link RS232 or RS485 to JBUS/MODBUS protocol • 115,200 Bauds
› USB port
› Serial link RS232 or RS485 to JBUS/MODBUS protocol • 115,200 Bauds
› USB port
Power Supply
› Low voltage power supply: 10-32V dc
› Peak consumption < 12W
› Average consumption < 6W
› Low voltage power supply: 10-32V dc
› Peak consumption < 12W
› Average consumption < 6W
› Low voltage power supply: 10-32V dc
› Peak consumption < 12W
› A verage consumption < 6W
› Low voltage power supply: 10-32V dc
› Peak consumption < 12W
› Average consumption < 6W
› Low voltage power supply: 10-32V dc
› Peak consumption < 12W
›  Average consumption < 6W
Enclosure
Metallic • Robust and compact • 2kg • 221 x 231 x 59mm
Metallic • Robust and compact • 2kg • 221 x 231 x 59mm
Metallic • Robust and compact • 2kg • 221 x 231 x 59mm
Metallic • Robust and compact • 2kg • 221 x 231 x 59mm
Metallic • Robust and compact • 2kg • 221 x 231 x 59mm
Protection
IP 67
IP 67
IP 67
IP 67
IP 67
Temperature range
For use from -20°C to 70°C (Screen reading from -20°C to 60°C)
For use from -20°C to 70°C (Screen reading from -20°C to 60°C)
For use from -20°C to 70°C (Screen reading from -20°C to 60°C)
For use from -20°C to 70°C (Screen reading from -20°C to 60°C)
For use from -20°C to 70°C (Screen reading from -20°C to 60°C)

REQUEST FORM