Uf 821 CO -FLOW METER

Model
Single channel
MULTI-channel
River
Nature of equipment
Fixed
Fixed
Fixed
Measurement on pipe
under load
Yes
Yes
Yes
Flow measurement on
open channel
No
No
No
Width of channel
Up to 30m in clear water
Up to 30m in clear water
Up to 300m in clear water
Standard mounted
inputs/outputs
2 isolated current inputs 4-20mA, 0-20mA, 0-24mA (single module) *
* For 4 channels, 2 modules are required (4 inputs)
2 isolated current inputs 4-20mA, 0-20mA, 0-24mA (single module) *
* For 4 channels, 2 modules are required (4 inputs)
2 isolated current inputs 4-20mA, 0-20mA, 0-24mA (single module) *
* For 4 channels, 2 modules are required (4 inputs)
In option , single
input/output modules
Up to 3 single modules to choose from:
› 1 isola ted, ac tive analogue output: curr ent 4-20mA, 0-20mA, 0-24mA • Module 1 ( Single)
› 2 st atic r elay output s usable as fr equency output s ( up t o 1kHz) • Module 2 ( Single)
› 2 isola ted curr ent input s 4-20mA, 0-20mA, 0-24mA • Module 3 ( Single)
› 2 isola ted, passiv e analogue 0-10V input s: 0 t o 15V v oltage • Module 4 ( Single)
› 2 P T100/PT1000 t emperature input s - t aking up the ph ysical space o f 2 modules • Module 5 (Dual)
› 2 con tact 5 V input s ( pulse or st ate) • Module 6 ( Single)
Up to 3 single modules to choose from:
› 1 isola ted, ac tive analogue output: curr ent 4-20mA, 0-20mA, 0-24mA • Module 1 ( Single)
› 2 st atic r elay output s usable as fr equency output s ( up t o 1kHz) • Module 2 ( Single)
› 2 isola ted curr ent input s 4-20mA, 0-20mA, 0-24mA • Module 3 ( Single)
› 2 isola ted, passiv e analogue 0-10V input s: 0 t o 15V v oltage • Module 4 ( Single)
› 2 P T100/PT1000 t emperature input s - t aking up the ph ysical space o f 2 modules • Module 5 (Dual)
› 2 con tact 5 V input s ( pulse or st ate) • Module 6 ( Single)
Up to 3 single modules to choose from:
› 1 isola ted, ac tive analogue output: curr ent 4-20mA, 0-20mA, 0-24mA • Module 1 ( Single)
› 2 st atic r elay output s usable as fr equency output s ( up t o 1kHz) • Module 2 ( Single)
› 2 isola ted curr ent input s 4-20mA, 0-20mA, 0-24mA • Module 3 ( Single)
› 2 isola ted, passiv e analogue 0-10V input s: 0 t o 15V v oltage • Module 4 ( Single)
› 2 P T100/PT1000 t emperature input s - t aking up the ph ysical space o f 2 modules • Module 5 (Dual)
› 2 con tact 5 V input s ( pulse or st ate) • Module 6 ( Single)
Use
Flow measurement in a channel
with the ability to incorporate
up to 4 speed chords (optimum
accuracy for difficult hydraulic
conditions)
Flow measurement in 1 to
4 channels with the ability to incorporate
up to 4 speed chords
(depending on the configuration
chosen)
Flow measurement in a river
with the ability to incorporate
up to 4 speed chords
IN OPTION
› HART protocole
› HART protocole
› HART protocole
Display
› Graphical LCD screen (14 lines x 20 characters)
› Backlit screen with time delay feature
› Graphical LCD screen (14 lines x 20 characters)
› Backlit screen with time delay feature
› Graphical LCD screen (14 lines x 20 characters)
› Backlit screen with time delay feature
Troubleshooting help
Oscilloscope function (echo displayed) • Gain • Quality index
Oscilloscope function (echo displayed) • Gain • Quality index
Oscilloscope function (echo displayed) • Gain • Quality index
Set-up
› Quick and simple - by 7 - key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› Possible to build in an access code
› Quick and simple - by 7 - key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› Possible to build in an access code
› Quick and simple - by 7 - key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› Possible to build in an access code
Information storage
› 8MB data logger: time st amping - 1 to 30 variables - up to 536,886 lines
› L ogging frequency from 1 second to 24 hours
› 8MB data logger: time st amping - 1 to 30 variables - up to 536,886 lines
› L ogging frequency from 1 second to 24 hours
› 8MB data logger: time st amping - 1 to 30 variables - up to 536,886 lines
› L ogging frequency from 1 second to 24 hours
Operating system
Windows for transfer of content and operation of logger using common software (Excel, etc.)
Windows for transfer of content and operation of logger using common software (Excel, etc.)
Windows for transfer of content and operation of logger using common software (Excel, etc.)
7 langua ges
French • English • German • Portuguese • Spanish • Italian • Russian
French • English • German • Portuguese • Spanish • Italian • Russian
French • English • German • Portuguese • Spanish • Italian • Russian
COMMUNICATION
› Serial link RS232 and RS 485 to JBUS/MODBUS protocol • 115,200 Bauds
› USB Port
› Serial link RS232 and RS 485 to JBUS/MODBUS protocol • 115,200 Bauds
› USB Port
› Serial link RS232 and RS 485 to JBUS/MODBUS protocol • 115,200 Bauds
› USB Port
Power supply
› DC power supply: 10-32V dc • Peak consumption < 12W • Average consumption < 6W
› AC power supply: 110-240V ac • Peak consumption < 15W • Average consumption < 7,5W
› DC power supply: 10-32V dc • Peak consumption < 12W • Average consumption < 6W
› AC power supply: 110-240V ac • Peak consumption < 15W • Average consumption < 7,5W
› DC power supply: 10-32V dc • Peak consumption < 12W • Average consumption < 6W
› AC power supply: 110-240V ac • Peak consumption < 15W • Average consumption < 7,5W
Enclosure
› Fibreglass-reinforced polycarbonate V0 • PG11 and PG13 gland connectors
› Weight: 3kg • Dimensions: 290mm x 285mm x 100mm
› Fibreglass-reinforced polycarbonate V0 • PG11 and PG13 gland connectors
› Weight: 3kg • Dimensions: 290mm x 285mm x 100mm
› Fibreglass-reinforced polycarbonate V0 • PG11 and PG13 gland connectors
› Weight: 3kg • Dimensions: 290mm x 285mm x 100mm
Protection
IP 67
IP 67
IP 67
Temperature range
For use from - 20°C to + 60°C
For use from - 20°C to + 60°C
For use from - 20°C to + 60°C

REQUEST FORM
uf 821 co -flow meter