Uf 831CO /UF831RV-FLOW METER

Uf 831CO /UF831RV-FLOW METER
 
 
Model
Single Channel
Multi-Channel
River
Nature of equipment
Fixed
Fixed
Fixed
Width of channel
Up to 30m in clear water
Up to 30m in clear water
Up to 30m in clear water
Use
Flow measurement in a channel
with the ability to incorporate up
to eight speed chords (optimum
accuracy for difficult hydraulic
conditions)
Flow measurement in one to
eight channels with the ability
to incorporate up to eight
speed chords (depending
on the configuration chosen)
Flow measurement in one to
eight channels with the ability
to incorporate up to eight
speed chords (depending
on the configuration chosen)
Input/output
› With Field bus option: up to 5 programmable input/output modules
› Without Field bus option: up to 10 programmable input/output modules
› With Field bus option: up to 5 programmable input/output modules
› Without Field bus option: up to 10 programmable input/output modules
› With Field bus option: up to 5 programmable input/output modules
› Without Field bus option: up to 10 programmable input/output modules
3 to 6 mandatory
base modules
› 1 isolated active analogue output: current 4-20mA, 0-20mA, 0-24mA
› 2 static relay digital outputs (50V - 10mA) usable on frequency outputs
› 2 isolated current inputs 4-20mA, 0-20mA, 0-24mA*
*Multi-channel versions :
4 channels: 2 isolated current input modules 4-20mA, 0-20mA, 0-24mA (4 inputs)
6 channels: 3 isolated current input modules 4-20mA, 0-20mA, 0-24mA (6 inputs)
8 channels: 4 isolated current input modules 4-20mA, 0-20mA, 0-24mA (8 inputs)
› 1 isolated active analogue output: current 4-20mA, 0-20mA, 0-24mA
› 2 static relay digital outputs (50V - 10mA) usable on frequency outputs
› 2 isolated current inputs 4-20mA, 0-20mA, 0-24mA*
*Multi-channel versions :
4 channels: 2 isolated current input modules 4-20mA, 0-20mA, 0-24mA (4 inputs)
6 channels: 3 isolated current input modules 4-20mA, 0-20mA, 0-24mA (6 inputs)
8 channels: 4 isolated current input modules 4-20mA, 0-20mA, 0-24mA (8 inputs)
› 1 isolated active analogue output: current 4-20mA, 0-20mA, 0-24mA
› 2 static relay digital outputs (50V - 10mA) usable on frequency outputs
› 2 isolated current inputs 4-20mA, 0-20mA, 0-24mA*
*Multi-channel versions :
4 channels: 2 isolated current input modules 4-20mA, 0-20mA, 0-24mA (4 inputs)
6 channels: 3 isolated current input modules 4-20mA, 0-20mA, 0-24mA (6 inputs)
8 channels: 4 isolated current input modules 4-20mA, 0-20mA, 0-24mA (8 inputs)
In option,
other modules
available
› 1 isola ted ac tive analogue output: ur rent 4-20mA, 0-20mA, 0-24mA • Module 1
› 2 st atic r elay output s usable as fr equency output s ( up t o 1kHz) • Module 2
› 2 isola ted ur rent input s 4-20mA, 0-20mA, 0-24mA • Module 3
› 2 0-10V v oltage input s • Module 4
› 2 P T100/PT1000 t emperature input s • Module 5
› 2 con tact input s ( pulse or st ate) • Module 6
› 1 isola ted ac tive analogue output: ur rent 4-20mA, 0-20mA, 0-24mA • Module 1
› 2 st atic r elay output s usable as fr equency output s ( up t o 1kHz) • Module 2
› 2 isola ted ur rent input s 4-20mA, 0-20mA, 0-24mA • Module 3
› 2 0-10V v oltage input s • Module 4
› 2 P T100/PT1000 t emperature input s • Module 5
› 2 con tact input s ( pulse or st ate) • Module 6
› 1 isola ted ac tive analogue output: ur rent 4-20mA, 0-20mA, 0-24mA • Module 1
› 2 st atic r elay output s usable as fr equency output s ( up t o 1kHz) • Module 2
› 2 isola ted ur rent input s 4-20mA, 0-20mA, 0-24mA • Module 3
› 2 0-10V v oltage input s • Module 4
› 2 P T100/PT1000 t emperature input s • Module 5
› 2 con tact input s ( pulse or st ate) • Module 6
In option,
Communication
protocol
- Field bus -
Choice of 2 buses:
› Modbus TCP
› M odbus RT U
Note: physically takes the place of 5 input/output modules
Choice of 2 buses:
› Modbus TCP
› M odbus RT U
Note: physically takes the place of 5 input/output modules
Choice of 2 buses:
› Modbus TCP
› M odbus RT U
Note: physically takes the place of 5 input/output modules
Display
› Numeric and graphical (14 lines x 20 characters)
› B acklit LCD screen with time delay feature
› Numeric and graphical (14 lines x 20 characters)
› B acklit LCD screen with time delay feature
› Numeric and graphical (14 lines x 20 characters)
› B acklit LCD screen with time delay feature
Troubleshooting help
Oscilloscope func tion ( echo displa yed) • Gain • Quality inde x
Oscilloscope func tion ( echo displa yed) • Gain • Quality inde x
Oscilloscope func tion ( echo displa yed) • Gain • Quality inde x
Set-up
› Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› P ossible to build in an access code
› Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› P ossible to build in an access code
› Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied
› P ossible to build in an access code
Information storage
› 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 data items
› 3- variable time-st amping: 2 68,443 lines • 14 v ariables: 7 1,584 lines • 30 v ariables: 34, 637 lines
› Logging frequency from 1 second to 24 hours
› 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 data items
› 3- variable time-st amping: 2 68,443 lines • 14 v ariables: 7 1,584 lines • 30 v ariables: 34, 637 lines
› Logging frequency from 1 second to 24 hours
› 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 data items
› 3- variable time-st amping: 2 68,443 lines • 14 v ariables: 7 1,584 lines • 30 v ariables: 34, 637 lines
› Logging frequency from 1 second to 24 hours
Operating system
Windows for transfer of content and operation of logger using common software (Excel, etc.)
Windows for transfer of content and operation of logger using common software (Excel, etc.)
Windows for transfer of content and operation of logger using common software (Excel, etc.)
7 languages
French • English • German • Portuguese • Spanish • Italian • Russian
French • English • German • Portuguese • Spanish • Italian • Russian
French • English • German • Portuguese • Spanish • Italian • Russian
Serial link
RS232 or RS 485 t o JBUS /MODBUS pr otocol • 115,200 Bauds
RS232 or RS 485 t o JBUS /MODBUS pr otocol • 115,200 Bauds
RS232 or RS 485 t o JBUS /MODBUS pr otocol • 115,200 Bauds
Choice of power supply
Low v oltage: 9- 36V dc • Mains : 110 t o 2 40V ac
Low v oltage: 9- 36V dc • Mains : 110 t o 2 40V ac
Low v oltage: 9- 36V dc • Mains : 110 t o 2 40V ac
Enclosure
Stainless st eel 30 4, epo xy pain t • Plug-in connec tors • 8k g • 300 x 346 .5 x 148mm
Stainless st eel 30 4, epo xy pain t • Plug-in connec tors • 8k g • 300 x 346 .5 x 148mm
Stainless st eel 30 4, epo xy pain t • Plug-in connec tors • 8k g • 300 x 346 .5 x 148mm
Protection
IP67 (except with field bus option: IP20)
IP67 (except with field bus option: IP20)
IP67 (except with field bus option: IP20)
Temperature range
For use from -10°C to 50°C
For use from -10°C to 50°C
For use from -10°C to 50°C

REQUEST FORM
uf 831co /uf831rv-flow meter