Model | Single Channel | Multi-Channel | River |
Nature of equipment | Fixed | Fixed | Fixed |
Width of channel | Up to 30m in clear water | Up to 30m in clear water | Up to 30m in clear water |
Use | Flow measurement in a channel with the ability to incorporate up to eight speed chords (optimum accuracy for difficult hydraulic conditions) | Flow measurement in one to eight channels with the ability to incorporate up to eight speed chords (depending on the configuration chosen) | Flow measurement in one to eight channels with the ability to incorporate up to eight speed chords (depending on the configuration chosen) |
Input/output | › With Field bus option: up to 5 programmable input/output modules › Without Field bus option: up to 10 programmable input/output modules | › With Field bus option: up to 5 programmable input/output modules › Without Field bus option: up to 10 programmable input/output modules | › With Field bus option: up to 5 programmable input/output modules › Without Field bus option: up to 10 programmable input/output modules |
3 to 6 mandatory base modules | › 1 isolated active analogue output: current 4-20mA, 0-20mA, 0-24mA › 2 static relay digital outputs (50V - 10mA) usable on frequency outputs › 2 isolated current inputs 4-20mA, 0-20mA, 0-24mA* *Multi-channel versions : 4 channels: 2 isolated current input modules 4-20mA, 0-20mA, 0-24mA (4 inputs) 6 channels: 3 isolated current input modules 4-20mA, 0-20mA, 0-24mA (6 inputs) 8 channels: 4 isolated current input modules 4-20mA, 0-20mA, 0-24mA (8 inputs) | › 1 isolated active analogue output: current 4-20mA, 0-20mA, 0-24mA › 2 static relay digital outputs (50V - 10mA) usable on frequency outputs › 2 isolated current inputs 4-20mA, 0-20mA, 0-24mA* *Multi-channel versions : 4 channels: 2 isolated current input modules 4-20mA, 0-20mA, 0-24mA (4 inputs) 6 channels: 3 isolated current input modules 4-20mA, 0-20mA, 0-24mA (6 inputs) 8 channels: 4 isolated current input modules 4-20mA, 0-20mA, 0-24mA (8 inputs) | › 1 isolated active analogue output: current 4-20mA, 0-20mA, 0-24mA › 2 static relay digital outputs (50V - 10mA) usable on frequency outputs › 2 isolated current inputs 4-20mA, 0-20mA, 0-24mA* *Multi-channel versions : 4 channels: 2 isolated current input modules 4-20mA, 0-20mA, 0-24mA (4 inputs) 6 channels: 3 isolated current input modules 4-20mA, 0-20mA, 0-24mA (6 inputs) 8 channels: 4 isolated current input modules 4-20mA, 0-20mA, 0-24mA (8 inputs) |
In option, other modules available | › 1 isola ted ac tive analogue output: ur rent 4-20mA, 0-20mA, 0-24mA • Module 1 › 2 st atic r elay output s usable as fr equency output s ( up t o 1kHz) • Module 2 › 2 isola ted ur rent input s 4-20mA, 0-20mA, 0-24mA • Module 3 › 2 0-10V v oltage input s • Module 4 › 2 P T100/PT1000 t emperature input s • Module 5 › 2 con tact input s ( pulse or st ate) • Module 6 | › 1 isola ted ac tive analogue output: ur rent 4-20mA, 0-20mA, 0-24mA • Module 1 › 2 st atic r elay output s usable as fr equency output s ( up t o 1kHz) • Module 2 › 2 isola ted ur rent input s 4-20mA, 0-20mA, 0-24mA • Module 3 › 2 0-10V v oltage input s • Module 4 › 2 P T100/PT1000 t emperature input s • Module 5 › 2 con tact input s ( pulse or st ate) • Module 6 | › 1 isola ted ac tive analogue output: ur rent 4-20mA, 0-20mA, 0-24mA • Module 1 › 2 st atic r elay output s usable as fr equency output s ( up t o 1kHz) • Module 2 › 2 isola ted ur rent input s 4-20mA, 0-20mA, 0-24mA • Module 3 › 2 0-10V v oltage input s • Module 4 › 2 P T100/PT1000 t emperature input s • Module 5 › 2 con tact input s ( pulse or st ate) • Module 6 |
In option, Communication protocol - Field bus - | Choice of 2 buses: › Modbus TCP › M odbus RT U Note: physically takes the place of 5 input/output modules | Choice of 2 buses: › Modbus TCP › M odbus RT U Note: physically takes the place of 5 input/output modules | Choice of 2 buses: › Modbus TCP › M odbus RT U Note: physically takes the place of 5 input/output modules |
Display | › Numeric and graphical (14 lines x 20 characters) › B acklit LCD screen with time delay feature | › Numeric and graphical (14 lines x 20 characters) › B acklit LCD screen with time delay feature | › Numeric and graphical (14 lines x 20 characters) › B acklit LCD screen with time delay feature |
Troubleshooting help | Oscilloscope func tion ( echo displa yed) • Gain • Quality inde x | Oscilloscope func tion ( echo displa yed) • Gain • Quality inde x | Oscilloscope func tion ( echo displa yed) • Gain • Quality inde x |
Set-up | › Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied › P ossible to build in an access code | › Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied › P ossible to build in an access code | › Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied › P ossible to build in an access code |
Information storage | › 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 data items › 3- variable time-st amping: 2 68,443 lines • 14 v ariables: 7 1,584 lines • 30 v ariables: 34, 637 lines › Logging frequency from 1 second to 24 hours | › 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 data items › 3- variable time-st amping: 2 68,443 lines • 14 v ariables: 7 1,584 lines • 30 v ariables: 34, 637 lines › Logging frequency from 1 second to 24 hours | › 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 data items › 3- variable time-st amping: 2 68,443 lines • 14 v ariables: 7 1,584 lines • 30 v ariables: 34, 637 lines › Logging frequency from 1 second to 24 hours |
Operating system | Windows for transfer of content and operation of logger using common software (Excel, etc.) | Windows for transfer of content and operation of logger using common software (Excel, etc.) | Windows for transfer of content and operation of logger using common software (Excel, etc.) |
7 languages | French • English • German • Portuguese • Spanish • Italian • Russian | French • English • German • Portuguese • Spanish • Italian • Russian | French • English • German • Portuguese • Spanish • Italian • Russian |
Serial link | RS232 or RS 485 t o JBUS /MODBUS pr otocol • 115,200 Bauds | RS232 or RS 485 t o JBUS /MODBUS pr otocol • 115,200 Bauds | RS232 or RS 485 t o JBUS /MODBUS pr otocol • 115,200 Bauds |
Choice of power supply | Low v oltage: 9- 36V dc • Mains : 110 t o 2 40V ac | Low v oltage: 9- 36V dc • Mains : 110 t o 2 40V ac | Low v oltage: 9- 36V dc • Mains : 110 t o 2 40V ac |
Enclosure | Stainless st eel 30 4, epo xy pain t • Plug-in connec tors • 8k g • 300 x 346 .5 x 148mm | Stainless st eel 30 4, epo xy pain t • Plug-in connec tors • 8k g • 300 x 346 .5 x 148mm | Stainless st eel 30 4, epo xy pain t • Plug-in connec tors • 8k g • 300 x 346 .5 x 148mm |
Protection | IP67 (except with field bus option: IP20) | IP67 (except with field bus option: IP20) | IP67 (except with field bus option: IP20) |
Temperature range | For use from -10°C to 50°C | For use from -10°C to 50°C | For use from -10°C to 50°C |