Model | Single Pipe | Multi-Pipe |
Nature of equipment | Fixed | Fixed |
Internal diameter of pipe | From 8mm to 9,900mm approximately (depending on wall thickness) | From 8mm to 9,900mm approximately (depending on wall thickness) |
External diameter of pipe | From 10mm to 10,000mm | From 10mm to 10,000mm |
input/output | › With Field bus option: Up to 5 programmable input/output modules | › With Field bus option: Up to 5 programmable input/output modules |
2 mandatory base modules | › 1 isolated active analogue output: current 4-20mA, 0-20mA, 0-24mA (single module) | › 1 isolated active analogue output: current 4-20mA, 0-20mA, 0-24mA (single module) |
In option, other modules available | › 1 isolated, active analogue output: current 4-20mA, 0-20mA, 0-24mA • Module 1 (single) › 2 static relay outputs (50V - 10mA) usable as frequency outputs (up to 1kHz) • Module 2 (single) › 2 isolated, passive current inputs 4-20mA, 0-20mA, 0-24mA • Module 3 (single) › 2 isolated, passive analogue 0-10V inputs: 0 to 15V voltage • Module 4 (single) › 2 temperature inputs PT 100/PT 1000 • Module 5 (dual) › 2 contact 5V inputs (pulse or state) • Module 6 (single) | › 1 isolated, active analogue output: current 4-20mA, 0-20mA, 0-24mA • Module 1 (single) › 2 static relay outputs (50V - 10mA) usable as frequency outputs (up to 1kHz) • Module 2 (single) › 2 isolated, passive current inputs 4-20mA, 0-20mA, 0-24mA • Module 3 (single) › 2 isolated, passive analogue 0-10V inputs: 0 to 15V voltage • Module 4 (single) › 2 temperature inputs PT 100/PT 1000 • Module 5 (dual) › 2 contact 5V inputs (pulse or state) • Module 6 (single) |
in option, calorimetric function | › 2 temperature inputs PT 100/PT 1000 • Module 5 + 2 probes PT 100 + 2 2.5m cables | › 2 temperature inputs PT 100/PT 1000 • Module 5 + 2 probes PT 100 + 2 2.5m cables |
Use | Flow measurement in a pipe with the ability to incorporate up to eight speed chords (optimised accuracy for difficult hydraulic conditions) | Flow measurement in a pipe with the ability to incorporate up to eight speed chords (optimised accuracy for difficult hydraulic conditions) |
Option, Communication protocol - Field bus- | Choice of 2 buses: › Modbus TCP › M odbus RT U Note: physically takes the place of 5 input/output modules | Choice of 2 buses: › Modbus TCP › M odbus RT U Note: physically takes the place of 5 input/output modules |
Display | › N umeric and graphical (14 lines x 20 characters) › B acklit LCD screen with time delay feature | › N umeric and graphical (14 lines x 20 characters) › B acklit LCD screen with time delay feature |
Troubleshooting help | Oscilloscope function (echo displayed) • Gain • Quality index | Oscilloscope function (echo displayed) • Gain • Quality index |
Set-up | › Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied › Possible to build in an access code | › Quick and simple - by 7-key touchpad with 2 dynamically allocated - or - via dedicated software supplied › Possible to build in an access code |
Information storage | › 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 data items › 3-variable time-stamping: 268,443 lines • 14 variables: 71,584 lines • 30 variables: 34,637 lines › Logging frequency from 1 second to 24 hours | › 8MB data logger: time stamping - 1 to 30 variables - up to 536,886 data items › 3-variable time-stamping: 268,443 lines • 14 variables: 71,584 lines • 30 variables: 34,637 lines › Logging frequency from 1 second to 24 hours |
Operating system | Windows for transfer of content and operation of logger using common software (Excel, etc.) | Windows for transfer of content and operation of logger using common software (Excel, etc.) |
7 languages | French • English • German • Portuguese • Spanish • Italian • Russian | French • English • German • Portuguese • Spanish • Italian • Russian |
Serial link | RS232 or RS485 to JBUS/MODBUS protocol • 115,200 Bauds | RS232 or RS485 to JBUS/MODBUS protocol • 115,200 Bauds |
Choice of power supply | Low voltage: 9-36V dc • Mains: 110 to 240V ac | Low voltage: 9-36V dc • Mains: 110 to 240V ac |
Enclosure | Stainless steel 304, epoxy paint • Plug-in connectors • 8kg • 300 x 346.5 x 148mm | Stainless steel 304, epoxy paint • Plug-in connectors • 8kg • 300 x 346.5 x 148mm |
Protection | IP67 (except with field bus option: IP20) | IP67 (except with field bus option: IP20) |
Temperature range | For use from -10°C to 50°C | For use from -10°C to 50°C |